Probes and sites
Probes and sites
The Probes menu is where you look after your probes, your sites and the readings they produce. SmartProbe adds your probes and allocates them to your sites. You name them, set their limits and choose who sees which site.
- Probe Logs: any probe's readings over a period, with reports and exports.
- Devices: your probes, whether each is reporting, and their limits and calibration. See Devices.
- Locations: your sites and the SmartProbe tablet at each one.
Sites
A site is one physical place with one SmartProbe tablet collecting its probe readings. Its name and time zone appear on its readings, reports and alerts.
- Locations shows each site's Tablet status: Sending readings (a reading in the last 24 hours), Gone quiet (nothing for 1 to 7 days; it usually catches up by itself), Offline (nothing for over 7 days) or No readings yet.
- The Not reporting tab lists tablets that need checking. For an offline tablet, check it is switched on, on the Wi-Fi and logged in.
- A site's page shows its probes, calibration due soon, who has Access, the tablet's login under Tablet setup, and its Connection history.
Adding and changing a site
Masters add a site with New location and set:
- Name: what your team calls it, such as "Main Kitchen".
- Timezone: must match where the site physically is, because its readings and audit exports are dated in it.
- Food safety supervisor: the certified supervisor's name and when their certificate expires.
- How often the tablet checks in: two minutes suits most sites.
Saving a new site creates the tablet's Access key and Secret, shown under Tablet setup. If a tablet is lost or replaced, use Replace tablet login details in the site's Settings; the old details stop working at once. Contact SmartProbe if a site has closed.
Who can see a site
- Masters see every site.
- Managers and Users see only the sites they've been given, from a site's Access tab or from Team Members → Manage Locations.
Probe Logs
Probe Logs is where you look back at readings: to check a fridge held temperature, look into an incident, or give evidence to an inspector or auditor.
- Choose the Location, Probe, Channels and Date Range, then press Apply.
- Read the summary, the chart with its warning limits, the incidents and excursions in the window, and Coverage (how many expected readings arrived, and every gap).
- Use Previous window and Next window to step through time, or Copy link to share the same search with a colleague.
- Export gives a Probe log report (PDF), CSV files or a workbook. Large exports are queued under Exports and kept for 30 days.
- Masters can email an export to colleagues or to an outside auditor (who opens it with a one-time code), and turn on Send this report regularly for a daily, weekly or monthly scheduled report.
Good to know
- Readings show in the time zone of the site where they were taken. A probe that moves keeps its earlier readings at its earlier site.
- Missing readings are not safe readings. Check Coverage before relying on a window.
- Incidents are raised automatically from each probe's limits. You don't raise them from Probe Logs.